1N Series ADU
The units are designed for air disinfection in microclimate systems of saloons of ground city public transport (buses, electric buses, trams, etc.).
No. n/a | Parameter name | Unit | Parameter value |
---|---|---|---|
1 | Performance | m3h | to 4400 |
2 | Supply mains voltage | V | 24 DC |
3 | Power consumption | W | to 500 |
4 | Number of UV lamps | pcs. | 2 |
5 | UV lamp type | Amalgam bactericidal for transport applications | |
6 | Number of control units | pcs. | 2 |
7 | Type of control units | Electronic | |
8 | Aerodynamic resistance max. | Pa | 100 |
9 | Bactericidal efficiency, not less | % | 95 (in accordance with SP 2.5.3650-20) |